25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump

25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump

Product Details

Product Tags

25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump

cutting-type submersible sewage pump adopts double-end mechanical seal and rotating impeller. The impeller is made of stainless steel, which is wear-resistant, non-clogging and non-winding. It has the advantages of small size, compact structure and easy portability. cutting submersible sewage pump is mainly used to discharge domestic wastewater, sewage, human feces and solid suspended solids and non-corrosive media containing short fiber paper chips, wood chips, starch, sediment, ore particles, etc. The temperature of the pumped liquid does not vary. Over 40℃, density not more than 1200kg/m3, ph value 6~9

image.jpg


25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump It has strong sewage passing capacity and good belt cutting performance. It can chop long fibers, plastics, paper, belts, cloth strips, straw, rope and other impurities in the sewage and discharge them. WQK sewage pump with cutting device is especially suitable for narrow working surfaces such as shipbuilding, communications, shipping, basements, and excavation of ponds and rivers, especially individual food processing plants, individual breeding sites, drilling industries, water pit wells, and paper mills , used in paint factories. 


切割泵cp11.jpg

Scope of application of  cutting submersible sewage pump


 cutting submersible sewage pump is mainly used for engineering sewage and domestic sewage.

like: 

(1) Sewage treatment and circulating water transportation for small and medium-sized enterprises.

(2) Slag slurry pumping in factories and mines such as food, papermaking, brewing, steel and non-ferrous metals, tanning, textiles, pharmaceuticals, cement plants, etc.

(3) Used in construction sites, engineering foundation construction, municipal facilities, and water plants.

(4) Sewage discharge from underground basements of various high-rise buildings, civil air defense pits, subways, etc.

(5) Chicken farms, pig farms, various breeding industries, fish ponds are used for pumping water to clear ponds, increasing oxygenation, pumping human and animal excrement and urine in septic tanks and other occasions.

Note: The main performance and data of the   cutting submersible sewage pump are the same as those of the wqk/qg type except that it does not have a cutting device.


25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump

Conditions for use of  cutting submersible sewage pump:


1. The medium temperature does not exceed 40℃.

2. The average weight of the medium does not exceed 500 kilograms per cubic meter.

3. The pH value of the liquid being pumped is 5 to 9.

4. During long-term operation, the part of the motor allowed to be exposed to the liquid surface shall not exceed l/2 of the height.


25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump

Precautions for use of  cutting submersible sewage pump

产品图1.jpg

(1) Before using the electric pump, you must first check whether the cable is damaged. When transporting and installing the water pump, cut the iron to pull or damage the cable to avoid accidents caused by water leakage after the cable ruptures. If the cable is hard to crack, the cable should be replaced immediately. And use a megohmmeter to check whether the insulation resistance of the electric pump is normal (the insulation resistance must not be less than 1 megohm)

(2) Recognize the grounding wire (the grounding wire is usually yellow or green or connected with a grounding mark), and connect the grounding wire according to the prescribed procedures. (Our factory's ground wire is equipped with a ground mark).

(3) Choose a suitable protector (such as leakage protector, air switch, phase failure overcurrent protector, etc.) and do not connect directly with a knife switch.

(4) Connect the power cord according to the standard, test the power supply, check whether the electric pump is operating normally, and determine whether the steering is correct. If the steering is incorrect, just swap any two of the three power cords (pay attention to the operation) The time cannot exceed half a minute).

(5) Install the water outlet joint and water outlet hose (or iron pipe), tie a rope on the handle of the electric pump (cables must not be used to replace the hanging rope), put the electric pump into the liquid book to be pumped, and turn on the power supply and is ready to use.

(6) In order to ensure personal safety, when the electric pump is connected to power, it is strictly prohibited to install and launch water operations near the electric pump (such as moving or inspecting, troubleshooting, etc.) and touching the electric pump to prevent accidents caused by electric pump leakage!

(7) It is strictly prohibited for the entire electric pump to be exposed to the water for long-term operation (or short-term operation). The "start" and "stop" of the electric pump should not be too frequent to prevent overheating and damage to the motor.

(8) Long-term pumping of liquids with high sand content will cause greater wear and tear on the flow-passing parts of the   sewage pump with cutting device. It is recommended to use our cyclonic sewage submersible electric pump product.

(9) If it is found that the   sewage pump with cutting device does not rotate, the protector trips, the fuse blows out and other abnormal phenomena when it is running, the power should be cut off immediately and check whether there are any problems with the power protector wiring, etc.

If these external devices are normal, the electric pump may be faulty and should not be used at this time to avoid an accident!



25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump


Related similar products:

50DFQK10-10-0.75 DFQK alloy knife cutting sewage pump DFQK belt cutting sewage pump DFQK septic tank sewage belt cutting sewage pump DFQK biogas tank sewage belt cutting sewage pump

DFQK alloy knife cutting sewage pump DFQK farm sewage belt cutting sewage pump DFQK household bathroom sewage belt cutting sewage pump DFQK municipal sewage belt cutting sewage pump

DFQK cutting sanitary napkin with cutting sewage pump DFQK cutting diapers with cutting sewage pump DFQK cutting plastic bag with cutting sewage pump DFQK cutting weeds with cutting sewage pump

100DFQK100-15-7.5 DFQK breeding farm cutting sewage pump 50DFQK12-10-1.1 DFQK alloy knife cutting sewage pump 80DFQK30-15-3 DFQK breeding farm cutting sewage pump 80DFQK80-20-7.5 DFQK alloy knife cutting sewage pump

100DFQK70-15-5.5 DFQK farm cutting sewage pump 80DFQK60-16-5.5 DFQK septic tank cutting sewage pump DFQK cutting towel glove with cutting sewage pump 65DFQK35-18-4 DFQK bathroom cutting sewage pump

50DFQK15-15-1.5 DFQK septic tank cutting sewage pump 65DFQK35-16-3 DFQK alloy knife cutting sewage pump 50DFQK15-20-3 DFQK family bathroom cutting sewage pump 50DFQK25-16-3 DFQK biogas tank cutting sewage pump

80DFQK35-12-2.2 DFQK biogas tank cutting sewage pump 65DFQK25-15-2.2 DFQK farm cutting sewage pump 50DFQK20-15-2.2 DFQK alloy knife cutting sewage pump 80DFQK50-18-4 DFQK alloy knife cutting sewage pump

Submersible sewage pump with cutting knife WQK/QG cutting device sewage pump WQK cutting device sewage pump WQK cutting submersible sewage pump


25DFQK6-27-1.5S Single Phase Stainless Steel Clog Free Cutting Pump


cutting submersible sewage pump maintenance


1. After each use, especially for thicker and more viscous slurries, it should be placed in clean water for a few minutes before storage.

2. After every 300 to 500 hours of use of the electric pump, the waist oil hole screw should be opened and replenished with pure No. 10 engine oil, and a mechanical seal should be used to maintain good lubrication. If a large amount of water is found in the oil chamber, it indicates that the mechanical seal has failed and should be replaced.

3. The electric pump should be managed and used by dedicated personnel, and the insulation resistance between the electric pump winding and the casing should be regularly checked to see if it is normal and must not be less than 0.5 megohms. Otherwise, the stator must be removed and dried, and the insulation resistance can be used only after the insulation resistance rises.

4. After the electric pump is started, if it is found that the flow rate is insufficient or the lift is lower than the specified value (unless the pipeline resistance is large or blocked), the direction may be reversed. At this time, the power supply should be disconnected and any two of the three phase wires of the cable should be swapped with each other. Finally, connect the new meter and start again.

5. After the electric pump is disassembled and repaired, the sealing performance must be checked by a 0.2MPa air tightness test.

6. If the elbow and electric pump are placed separately in the crate, please install the elbow on the electric pump. If the electric pump is connected to the pipeline, there is no need to install the elbow.



  • PREVIOUS:25WQD3-12-0.37 220V Stainless Steel Septic Tank Cutting Pump